SML-DSLA-IP+ Professional IP Network Multifunction Cable Tracer
Professional IP tester with all nine network functions, 0.01 m-resolution TDR length testing, PoE checks, and energized-cable tracing.

Product Overview
The SML-DSLA-IP+ combines all nine professional IP/network functions, 0.01 m-resolution TDR length testing, and concealed-circuit tracing at 220 V or below. It also covers network-cable tracing and mapping, PoE checks, and multi-cable tracing for technicians handling cabling, network, and line-location work at the same site.
The product image shows the general series appearance. The panel and interfaces vary by model; refer to the corresponding unit.
IP / IP+ Feature Editions
| Network function | IP entry edition | IP+ professional edition |
|---|---|---|
| IP scan | Supported | Supported |
| PING | Supported | Supported |
| Port blink | Supported | Supported |
| Link speed | Supported | Supported |
| IP monitoring | — | Supported |
| HTTP test | — | Supported |
| LLDP | — | Supported |
| Network sniffing | — | Supported |
| Broadcast monitoring | — | Supported |
IP configuration is a shared setup function used by both editions and is not counted as a separate feature tier. Choose the SML-DSLA-IP when only the four entry network functions are required.
Typical Applications
- Locating network cables and checking wire map, continuity, and TDR length
- Checking PoE port voltage and power type
- Inspecting IPv4 reachability, addresses, links, neighboring devices, and broadcast conditions
- Tracing telephone lines, two-core wires, and coaxial cable
- Locating the route of in-wall and underground circuits at 220 V or below
Use and Safety Limits
For length testing, the cable must be de-energized and its far end left open. Energized-cable tracing requires the specified accessories and is limited to circuits at 220 V or below; never connect the tester to a 380 V circuit. Actual depth varies with wall construction, burial depth, and site interference. The maximum permitted PoE test voltage is 60 V. Use IP scan, HTTP, network sniffing, and broadcast monitoring only on networks where you have authorization. LLDP results depend on peer-device support and configuration.
Features
- Integrated cable tracing and 2-to-8-conductor remote wire mapping
- TDR length testing with 0.01 m resolution and a 500 m maximum range
- Traces in-wall and underground cables energized at 220 V or below
- IP scan, PING, port blink, and link speed
- IP monitoring, HTTP test, LLDP, network sniffing, and broadcast monitoring
Specifications
| Model | SML-DSLA-IP+ |
|---|---|
| Product Category | Professional IP Network Multifunction Cable Tracer |
| Network Feature Edition | Professional Edition (IP+) |
| Displays | 2.4-inch color LCD on receiver; LED indicator on transmitter |
| PoE Test | Up to 60 V; standard/non-standard identification |
| Length Test | TDR; 0.01 m resolution; 500 m maximum |
| Energized-Cable Tracing | 220 V or below; 50 cm in-wall, 150 cm underground |
| IP Tests | PING, IP scan, IP monitoring, and HTTP test; IP configuration is a shared setup function |
| PING | IPv4 / ICMP Echo; 1 ms round-trip-time display resolution; up to 1,000 requests |
| IP Scan | IPv4 / ARP; up to 254 addresses per scan within the same broadcast domain |
| HTTP Test | Starts a temporary local web service accessible from the same subnet |
| Network Tests | Port blink, link speed, LLDP, network sniffing, and broadcast monitoring |
| Link Speed | 10 / 100 / 1000 Mbps; full or half duplex |
| LLDP | The peer device must support and enable LLDP |
| Broadcast Threshold | 500-2,000 pps |
| Tracing Distance | Network cable up to 500 m; coaxial cable 300 m |
| Power | 3.7 V / 1200 mAh transmitter; 7.4 V / 1000 mAh receiver |
| Operating Environment | -10°C to +60°C; 10% to 70% RH |